Brand Name : HCATM
Model Number : GML601-J
Place of Origin : XIAN
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : PIECE/WEEK
Delivery Time : 3 to 7 working days after payment
Packaging Details : Carton
GML601-J Integrated Ultrasonic Level Gauge
The integrated ultrasonic level gauge is widely used for liquid level and volume measurement of tanks, pools, and reservoirs, as well as for flow measurement in open channels.
Technical parameter
Product name | Split ultrasonic level difference meter |
Range | The conventional range is 5 m,10m, 15m, 20m (other ranges can be customized) |
Measurement accuracy | 0.5%-1.0% |
Resolution | 3mm or 0.1% (whichever is greater) |
Display | 128*64 dot matrix English LCD |
Analog output | 2 4~20mA/510Ω load |
Relay output | 2 groups of AC 250V-8A or DC 30V/5A state programmable (optional) |
Power supply | 220V AC+15% 50Hz or 24VDC 120mA optional |
Ambient temperature | display instrument (transmitter) -20~+60°C |
Communication | 485 communication |
Protection level | IP65 for display instrument, IP68 for probe |
Probe cable | conventional 10 meters, other specifications can be customized |
Product introduction | Ultrasonic level difference meter (material level, liquid level) is used to measure the liquid level or the difference in level of two different containers. The most common is to measure the water level before and after the coarse grid and the fine grid at the water inlet of the sewage treatment plant, and calculate the height of the water level difference, which is used to start the anti-fishing decontamination machine to remove the garbage. |
Example of water level control setting
For drainage
It is required that the water level in the pool is below 1 meter, and the water pump stops draining; the water level rises to 5 meters, and the water pump starts to drain
out.
The settings are as follows: Mode: High alarm. Alarm value: 5.00m; Alarm hysteresis: 4.00m.
For water intake
It is required that the water level in the pool is below 1 meter, and the water pump starts to enter the water; the water level rises to 5 meters, the water pump starts to stop the water intake.
The settings are as follows: Mode: Low alarm. Alarm value: 1.00m; Alarm hysteresis: 4.00m.